Using smartctl to get SMART status information on your hard drives. If you have a Dedicated Server your RAID should be of one of three ... cat /proc/mdstat smartctl -a /dev/sda smartctl -a /dev/sdb mdadm with smartmontools ... For some reason my disk keep dropping from the raid when running ... raidz2/3 with lsi controllers and nagios monitoring using smartctl. We have a RAID 5 array using ... values when using RAID and Intel Matrix Storage? Disks with TLER / ERC / CCTL & LCC [Table of drives] ... Use smartctl from ... or possibly a RAID array. It is unlikely that a hardware RAID controller will directly support smartmontools. Timeout Mismatch. Hi guys, I my server, I installed a RAID card because I didn't have enough SATA ports. mdadm with smartmontools ... For some reason my disk keep dropping from the raid when running ... raidz2/3 with lsi controllers and nagios monitoring using smartctl. GSmartControl is a graphical user interface for smartctl (from smartmontools package), which is a tool for querying and controlling SMART (Self-Monitoring, Analysis, and Reporting Technology) data on modern hard disk and solid-state drives. Check-Server-Raid Check RAID status. Also, you will need this patch to smartmontools smartctl.cpp, if it is not already in CVS by the time you read this. Unchecked. This section will mention some of the hardware concerns involved when running software RAID. Smartmontools with MegaRAID Controller. I can use the "smartctl -d ata -a /dev/sdb" command to read hard disk health status directly connected to my system. The smartctl utility (part of the smartmontools package) can be used on hard disk drives that fully implement the ATA-8 standard to control the TLER behavior by setting the SCT Error Recovery Control (scterc) parameter. smartctl utility. It works fine and I am able to boot after disconnecting any single HDD. In some cases smartmontools needs guidance from the user and this can be given by the '-d ata|scsi|sat|marvell|3ware,N' option in the smartctl utility and in smartd daemon's configuration file. Smartmontools is a set of applications that can test hard drives and read their hardware SMART statistics. One of the three drives is a hot spare and the other two are active in the RAID sets. RAID mode provides the greatest overall flexibility and upgradeability From Linux Raid Wiki. I have a Scientific Linux 6.5 server with a RAID with SSD disks. System reboots when I use smartctl with Adaptec RAID controller. I want to use smartd (part of smartmontools) to monitor the health of the drives and report errors to syslog (which I monitor using logcheck). Archived from groups: comp.sys.ibm.pc.hardware.storage Does anybody know how I can monitor disk self-test parameters of the striped discs on a RAID Hardware issues. Jump to: ... you should buy drives that are explicitly suitable for RAID. smartctl has pass-through modes for Windows has several schemes for naming devices. smartctl has pass-through modes for Jump to: ... you should buy drives that are explicitly suitable for RAID. Linux / UNIX: Smartctl Check Hard Disk Behind 3Ware RAID Card Posted on June 25, 2011 June 25, 2011 in Categories FreeBSD, Linux, Storage last updated June 25, Check-Server-Raid Check RAID status. System reboots when I use smartctl with Adaptec RAID controller. If you have a Dedicated Server your RAID should be of one of three ... cat /proc/mdstat smartctl -a /dev/sda smartctl -a /dev/sdb From Thomas-Krenn-Wiki. My guess would be that the RAID controller has abstracted the individual disks, ... How to use smartctl with cciss.